VINYL THERMO-GUARD PATIO DOOR SPECIFICATIONS
MATERIALS & CONSTRUCTION:
Door units shall be contructed from specially designed heavy gauge, extruded vinyl in accordance with Sunview engeneering standards drawings.
FRAME:Consists of head channel track, sloped sill track. Each corner of frame jointed by four long screws, fastened into integral extruded strengthening ribs in head and still sections.
SASH: Styles and rails constructed of heavy extruded vinyl tubular sections. Vertical styles to be reinforced with aluminum of galvanized steel tube. Panel styles machined to overlap with rails and joined by screws fastened into extruded bosses in panel head and still rails. All two-panel units reversible before or after installation.
WEATHER-STRIPPING: Panels with double weather-stripping with polipropilene pile with a Mylar fin seal running down the center of the pile to form a double perimeter seal except at frame where there are three weather seals (two polypropylene pile Mylar fin seal plus a flexible bulb seal).
HARDWARE: Positive action,heavy-duty security laminated latch,safety activated to eliminate keeper breakage.High impact diecast with baked aluminum finish and custom hardwood handle.Two-way adjustable steel keeper.Bumper stop for all sliding panels.Sliding panels equipped with two steel cadmium-plated tandem ball bearings,weather-sealed adjustable rollers at bottom.All screws self-tapping plated steel.High quality cylinder lock available as optional extra.
SCREEN: Frames of tubular aluminium extrusions fitted with 18x14 mesh reversible fiberglass insect screen cloth held by vinyl spline.Spring-loaded rollers with end adjustment screws mounted on each end of the head and sill rails.Positive action spring lock,die cast inside handle and an integral extruded outside pull.Screen provided with polypropylene pile bug strip.
GLAZING: Nominal 13/16"tempered sealed insulating glass with a 1/2"insulating air space between lites of 4 mm tempered safety glass.
ELECTION: (By Others) Vinyl Thermo-Guard erercted in prepared openings according to manufacturer's recommendations and installation instructions. Sealant furnished by others. Installation screws provided by manufacturer. Manufacturer assumes no liability for damages by the trades and or final cleaning of vinyl and glass.
PERFOMANCE: Vinyl Thermo-Guard meets or exceeds the specifications of CAN/CGSB-82. 1-M89/ Meets or exceeds ASTM standards tested in accordance to D4099-89.
|